Civil Work whit a Dry Fountain

Most dry fountains are installations that belong to the civil-work field. They are usually public projects designed to invigorate and embellish the cities’ common areas, especially squares, parks and gardens. This means that dry fountains must meet a series of basic requirements aiming to achieve a proper interaction between them and the pedestrians. They would be the following: Read More

  • Perimeter gutters must be installed in order to collect the fountain’s water and prevent outer water from entering the dry fountain’s area. The gutters must be covered by a metal grid – it can be made of cast iron, stainless steel, galvanized steel or any other corrosion-resistant material. When gutters mostly collect water from the fountain, it is usual that they dewater in the installation’s pits, canals or underground pool. In this case, it is advisable to include a filtering mesh to prevent outer dirt from making contact with the fountain’s water. Gutters that collect outer water (rainwater, irrigation water, cleaning water, etc.) usually dewater directly into the rainwater network and do not need to mount a filtering mesh.
  • Fuente seca de pavimento civil

  • It is important that the removable slab pavement bears a rough finish or a non-slip treatment in order to prevent accidents. It is also advisable that the grids and plates are equipped with proper tamper-proof fixation systems.
  • The fountain’s wet areas (that is, the ones containing water: pits, canals, pools and compensation deposits) must be properly waterproofed with the most adequate system or product. Among others, we can choose chlorinated-rubber paints, sheets (PVC or asphalt), etc. The sheets have one disadvantage: they are likely to be torn or pierced if make contact with some of the fountain’s elements (pumps, supporting plates, etc.).
  • Even though it is not compulsory, it is really interesting to protect the pipes that connect the fountain’s pits or canals with a solid concrete bed. This material will avoid the development of cracks or leaks in the pipes, caused by earth movements or the lack of a firm foundation. If pipes are made of metal (even of stainless steel), the concrete bed will prevent them from rusting too.
  • Dry fountains are always connected to an electrical panel. The panel can be located outdoors (inside a polyester cabinet) or into a technical room, together with the rest of the fountain’s mechanisms. Be that as it may, it must be positioned on a plastered-brick or concrete bench no less than 20cm high. This is a preventive measure that will keep the panel safe in case of flooding.
  • If the installation of an anemometer is basic in any type of fountain, this is all the more true in dry fountains. The anemometer must always be at least 3-4 meters above the ground, attached to an existent element (street lights, posts…) or to one installed for the purpose. The information about the wind speed and direction obtained by the device will be directly sent to the Control Panel. This panel will manage the fountain’s operation, in order to avoid excessive splashing in the event of strong wind.
  • The building of an auxiliary compensation deposit is an interesting option for dry fountains. The water flow that feeds the jets is vacuumed from this deposit and returns to it through the corresponding return pipes. This solution is especially recommended for dry fountains with communicated canals; it can also be adapted to other fountain types, though it is not advisable.

 

Rate this blog entry:

Comments

  • Guest
    Spence Tuesday, 10 October 2017

    Did you really mean to say, "dry fountains must meet a series of basic requirements aiming to achieve a proper interaction between them and the peasants."?

    The "peasants"...really?

  • Jesús Sánchez
    Jesús Sánchez Wednesday, 11 October 2017

    Hello Spence,
    Sorry because it was a mistake of translation to english. Now it is already corrected on the web.
    Regards,

Leave your comment

Guest
Guest Tuesday, 17 October 2017